© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Programming
F232059
42
Step Programming
Programming a Fill Temperature
Table 5 lists the required procedures to produce
specific results.
Table 5 shows that when HIGH water level is
programmed, the display indicator is H. When
MEDIUM level is programmed, the display indicator
is M. When LOW level is programmed, the display
indicator is L. When OVERFLOW is programmed,
the display indicator is O.
When the Warm key is pressed, the next key pressed
will be another temperature key (Hot, Cold, or Warm)
before selecting the level.
Use the following procedure to program a fill to a
specific temperature:
1. The computer must be in the Program Mode, and
the cycle programming sequence must be ready
for the next step.
2. Press the Cold key. If this is the second step of
hypothetical cycle 25, the display will read
C-0225. (HOT or WARM may be programmed
instead to control inlet valves during the first
three seconds of the fill. After the first three
seconds, the fill is the same regardless of the
prompt.) Press the key representing the desired
water level (Low, Medium, High, or Over). If
High is pressed, for example, the display will
read CH0225.
3. Press the Heat key. The display will read either
080F25 or 025C25, depending on whether
Fahrenheit or Centigrade is prompted.
Enter the desired fill temperature. Three digits
must be entered. If the desired temperature is less
than 100 degrees, the first digit must be 0. If
100 degrees Fahrenheit is entered, the display
will read 100F25.
The valid temperature range is 80-200 degrees
Fahrenheit and 25-93 degrees Centigrade. The
computer will not accept temperatures out of this
range. (The fill temperatures possible are
governed by the temperature of the available hot
water.)
4. Press the Enter key. The display will read
M---S. Now assign the maximum time to be
allowed for reaching the fill level in minutes and
seconds.
5. Press the Enter key, and go to the next step in the
cycle.
The computer will attempt to maintain the temperature
within a margin of plus or minus five degrees of the
target fill temperature during such a step.
Table 5
Fill Temperature Programming
Keys Pressed Display Valves Operating
Hot + Low + Enter HL 1 Hot Fill
Hot + Med + Enter HM 1 Hot Fill
Hot + High + Enter HH 1 Hot Fill
Hot + Over + Enter HO 1 Hot Fill
Cold + Low + Enter CL 1 Cold Fill
Cold + Med + Enter CM 1 Cold Fill
Cold + High + Enter CH 1 Cold Fill
Cold + Over + Enter CO 1 Cold Fill
Warm + Low + Enter WL 1 Hot Fill and 1 Cold Fill
Warm + Med + Enter WM 1 Hot Fill and 1 Cold Fill
Warm + High + Enter WH 1 Hot Fill and 1 Cold Fill
Warm + Over + Enter WO 1 Hot Fill and 1 Cold Fill
In addition to the standard fill temperatures, computer-controlled fill or overflow to a specific temperature is available.